DI-71x Ethernet Installation to a DHCP Network Problems and Resolutions for Windows 2000 and XP

View pdf View the pdf

On this Page

Symptoms

Cause

Resolution

Verify that your WinDaq Resource CD is dated September 2005 or later

Set your DI-71x to DHCP

Verify Firewall Settings

Create a Debug710.log file

Applies To

Symptoms

While installing WinDaq for your DI-71x Ethernet device on a DHCP network you encounter the following message:

"No DATAQ Instruments Devices Found"

Note: On a DHCP network an IP address is automatically assigned to your device every time it is powered up. On a static network you must manually assign the device an IP address. Check with your network administrator if you are unsure of your network configuration (DHCP or Static).

Cause

This could be the result of one or more of the following:

Outdated installation software

The DI-71x has been assigned a static IP address

Network broadcasts are blocked (firewall settings)

Resolution

To resolve these issues follow the steps below.

Verify that your WinDaq Resource CD is dated September 2005 or later

If your WinDaq Resource CD is dated earlier than September 2005 download the latest revision of WinDaq at: http://www.dataq.com/support/upgrades/record/index.php.

View the pdf for images

Run the WinDaq installation program. Did WinDaq install properly? If not proceed to the next step.

Set your DI-71x to DHCP

Make sure your DI-71x is set as a DHCP device.

  1. Click the "Add IP" button in the "No Devices Found" window.

    View the pdf for images

  2. Select your DI-71x (the MAC address of the instrument is located on the bottom of the device) from the "Manage IP Addresses" dialog box and click the "Set DHCP" button.

    View the pdf for images

Run the WinDaq installation program. Did WinDaq install properly? If not proceed to the next step.

Verify Firewall Settings

You must be able to send and receive data over your local area network in order to install and run WinDaq for your DI-71x Ethernet device.

We require and use the following ports:

10001

30178

6237

68

67

These ports cannot be blocked for TCP or UDP. Check with your IT department to verify that network broadcasts are not blocked for these ports.

Also, make sure that your Windows firewall does not block the WinDaq Installation Manager.

  1. Double-click on "Security Center" in the Windows "Control Panel."
  2. Under "Manage security settings for:" select "Windows Firewall."

    View the pdf for images

  3. Select the "Exceptions" tab from the "Windows Firewall" window and make sure that "InstallManager" is checked.

    View the pdf for images

Run the WinDaq installation program. Did WinDaq install properly? If not proceed to the next step.

Create a Debug710.log file

The Debug710.log file will provide information pertinent to your installation issue. The support staff at DATAQ Instruments will review the Debug710.log file and reply via phone or email with a solution.

  1. Download the Debug710.exe application at http://www.dataq.com/Debug710.zip.
  2. Unzip the Debug710.exe file into the directory where WinDaq is installed.
  3. Run the Debug710.exe application. This will generate a file called Debug710.log in the same directory.
  4. Email the Debug710.log file along with a description of the problem to support@dataq.com.