With its color monitor and internal memory the GL200 is a compact, lightweight, multi-channel data logger that provides 10 analog measurement channels, in addition to one channel each of discrete logic and pulse inputs. The GL200 also supports one external trigger input and one alarm output. The GL200 is equipped with a 3.5 MB internal flash memory to allow the direct capture of acquired data, and its built-in USB port may be used to connect any standard USB flash drive for incremental capacity. Alternatively, the USB interface may be connected to a PC to allow data upload in real time or from memory, as well as remote configuration and real time data acquisition.
Each GL200 analog channel can measure from 20 mV to 50 VFS across eleven programmable measurement ranges.
Each analog GL200 channel is electrically isolated from all others and from instrument ground to allow accurate and safe measurements in industrial applications where ground potential differences are common.
Use the GL200 to measure humidity with an optional sensor.
Use the GL200 to measure voltages, currents, 4-20 mA process currents, as well as thermocouple-based temperatures.
The GL200 provides one discrete input channel that can be used for counting and rotational speed measurement applications.
The GL200 may be programmed to calculate average value, peak value, minimum value, and rms.
Program the GL200 to trigger its alarm output as a function of analog input signal level judgment, pulse judgment, or logic pattern.
Sample intervals can be programmed to be one of sixteen values ranging from 100 ms to one hour.
The focal point of the GL200 is its 3.5" built-in color display that allows real time trending, data review, and complete instrument configuration.
Each GL200 channel allows up to four break points to be programmed for accurate scaling into meaningful units like psi, grams, newtons, gallons per minute, etc.
Use the GL200 to measure the binary status of any external system.
The GL200 allows data capture to be started or stopped based upon signal level, an external event, date/time, alarm, duration, or Boolean channel combinations. Analog signal triggers can be programmed based upon level and window tests: above threshold, below threshold, inside window, or outside window.
Power the GL200 from its provided international AC adaptor, from an optional built-in battery pack, or from any 9 to 24 VDC source using an optional cable.
Allows data transfer to the PC either in real time or from the GL200's memory. Also allows complete configuration of the GL200. Connect any standard USB Flash Drive to the USB port for external memory expansion.
The GL200 includes a Windows application for direct capture, measurement, and monitoring of GL200 data. In addition to waveform and data value capture and display, the application can export data to an Excel file for further analysis and report creation. The software includes built-in help for quick reference.
![]()